Lighting Load Calculator
Required lumens per room · fixture counts by type · ceiling, reflectance & daylight aware
1 Project settings
2 Fixture library
types & manufacturer lumen output| Type | Description | Lumens / unit | Watts | CCT (K) |
|---|
3 Rooms
area, ceiling, colour, glazing & fixturesProject totals
Method. Required lumens per room = (FC target × Area) ÷ (CU × LLF).
CU (coefficient of utilization) is derived from the Room Cavity Ratio — a function of ceiling height and room size —
with the ceiling and wall reflectances (white surfaces bounce more light, so fewer lumens are needed).
Baseline shows the simpler Area × FC figure that reconciles with the studio schedule.
The daylight credit is a nominal daytime offset (glazing × credit × orientation), capped at 50% so night lighting stays adequate.
Foot-candle targets follow the IES / Energy Trust residential & commercial guides and are editable per room.
A design aid — verify against a photometric layout for critical spaces.